Description
???? Full Model Code Analysis
330101-00-14-90-02-00
- ???? 00 = 0.0in Unthreaded
- ???? 14 = 1.4in Compact Case
- ???? 90 = 9.0m Long Cable
- ????️ 02 = Standard ClickLoc
- ???? 00 = No Certifications
⚡ Critical Performance Data for 330101-00-14-90-02-00
| Parameter | Value |
|---|---|
| DC Resistance (9m) | 9.87Ω ±0.50 |
| Temperature Range | -52°C to +260°C |
| Cable Capacitance | 69.9 pF/m (21.3 pF/ft) |
???? Industrial Application
LNG Storage Tank Monitoring →
Detects pump vibrations in -162°C liquefied natural gas facilities using 9m cables to maintain safe operator distance. Maintains ±0.025mm accuracy at cryogenic temperatures.
Detects pump vibrations in -162°C liquefied natural gas facilities using 9m cables to maintain safe operator distance. Maintains ±0.025mm accuracy at cryogenic temperatures.
???? Key Installation Specs
⚙️
Linear Range: 2.0mm
(80 mils)
????
Gap Setting: 1.27mm
(-9 Vdc)
⚠️
Seal Limit: >-34°C
Viton® O-Ring
???? Complete Package Contents
1. 1.4in Probe Body (Code 14) 2. 9.0m Cable Assembly (Code 90) 3. ClickLoc Connector Kit (Code 02)
Explore more detailed information in official datasheet here: 3300 XL 8 mm Proximity Transducer System Datasheet











0.0 Average Rating Rated (0 Reviews)