Description
Allen-Bradley 1794-IE4XOE2 Flex I/O Combination Analog Module
The Allen-Bradley 1794-IE4XOE2 combines analog input and output functionality in one compact Flex I/O module from Rockwell Automation. This versatile module provides four analog inputs and two analog outputs for precise signal handling.
Core Technical Specifications & Performance Data
- Brand: Allen-Bradley | Model: 1794-IE4XOE2
- Product Type: Combination Analog I/O Module for Flex I/O
- Analog Inputs: 4 Single-ended, Non-isolated Channels
- Input Types: 0-20mA, 4-20mA, 0-10VDC, ±10VDC
- Input Resolution: 12-bit unipolar / 11-bit plus sign bipolar
- Analog Outputs: 2 Single-ended, Non-isolated Channels
- Output Types: 0-20mA, 4-20mA, 0-10VDC, ±10VDC
- Output Resolution: 12-bit
- Conversion Method: Successive Approximation (Input), PWM (Output)
- Conversion Rate: 256μs per channel
- Accuracy: 0.20% FS @ 25°C (Input), 0.133% FS @ 25°C (Output)
Installation & Configuration Guide
- Mount the module on a standard 35mm DIN rail with a secure snap-on design.
- Use compatible terminal bases including 1794-TB2, TB3, TB3S, TB3T, or TB3TS.
- Configure each channel independently using Rockwell Automation software tools.
Environmental Ratings & Durability Features
- Operating Temperature: 0 to 55 °C (32 to 131 °F)
- Storage Temperature: -40 to 85 °C (-40 to 185 °F)
- Relative Humidity: 5% to 95% (non-condensing)
- Vibration Resistance: 5g @ 10-500 Hz per IEC 60068-2-6
- Shock Resistance: 30g per IEC 60068-2-27
- Noise Immunity: Excellent noise rejection for stable analog signals
- EMC Compatibility: Meets industrial electromagnetic compatibility standards
Comparison With Related Products
- For HART-enabled analog outputs, see the 1794-OE8H module.
- Consider the 1794-OF4I for isolated analog output applications.
Frequently Asked Questions (FAQ)
- What software do I need to configure this analog module?
You need Rockwell Automation’s Studio 5000 or RSLogix 5000 programming software. - Can I use different signal types on different channels simultaneously?
Yes, each channel configures independently for various signal types. - What is the minimum load impedance for voltage outputs?
The voltage outputs require a minimum load impedance of 1kΩ for proper operation. - Does this module support temperature sensor inputs directly?
No, you need signal conditioners for thermocouples or RTD temperature sensors. - What is the step response time for current inputs?
The current inputs reach 63% of final value in approximately 18.2 milliseconds.