Description
Product Overview
- Woodward 9905-969 is a Linknet 6-Channel Analog Input Module.
- It reads 4-20mA signals from field devices. Perfect for non-turbine tasks like sequencing and monitoring.
- This module works with the NetCon control system. It gives you low-cost distributed I/O.
- Each module has 6 analog channels. Easy to install on a DIN rail.
- The module comes in a plastic Phoenix terminal housing. Durable and compact.
Technical Specifications
- Brand & Model: Woodward 9905-969
- Dimensions: 14W x 11H x 4D inches
- Weight: 9.11 lbs
- Display: 2 lines x 24 characters
- Keypad: 30 multi-function keys
- Accuracy: 1% at 25°C
- Power supply input: 18 to 32 Vdc
- Input voltage (nominal): +24 Vdc at 1 A
- Temperature range: –40°C to +55°C (operating)
- Humidity tolerance: 95% at 20°C and 55°C for 48 hours
- Isolation ratings:
- Network to I/O channel: 277 Vac
- Power supply input to network: 277 Vac
- Power supply input to I/O channel: 500 V
- Country of origin: United States
- Availability: In Stock
Key Performance Data
- Input type: 4-20 mA analog (6 channels per module)
- Resolution: High resolution for precise process monitoring
- Linearity: Excellent linear response ensures accurate readings
- Noise immunity: Robust isolation (500V between power and I/O)
- Electromagnetic compatibility: Meets industrial standards for harsh environments
Network Architecture & Compatibility
- Each NetCon controller supports up to 240 LINKnet modules on four trunks.
- Each trunk holds up to 60 I/O modules. Uses simple twisted pair wires.
- Set the network address with two rotary switches (1 to 60). Match the MOE coder setting.
- Compatible with other LINKnet I/O types: thermocouple, RTD, discrete, relay output.
- Also works alongside Modicon Quantum systems via gateway integration.
Installation Guide
- Mount on DIN rail inside a control cabinet. Use the Phoenix terminal housing.
- Connect +24 Vdc power supply (18-32V range). Draws 1A max.
- Wire 4-20mA field signals to the six analog channels.
- Set the rotary switches for unique node address (1-60).
- Connect twisted pair wires to the NetCon controller trunk.
- Keep cables away from high-voltage lines for noise reduction.
Debug & Maintenance Convenience
- 2-line display shows real-time channel data and status.
- 30-key keypad allows on-site configuration without a PC.
- LED indicators help troubleshoot power and communication faults.
- Hot-swappable design? No – power down before replacement.
- Use MOE coder software for advanced diagnostics and rate group settings.
Typical Applications
- Gas turbine sequencing and monitoring (non-turbine control tasks).
- Remote analog signal collection in power plants.
- Industrial process monitoring – pressure, flow, temperature via 4-20mA sensors.
- Distributed I/O for NetCon based automation systems.
Diagnostic Capability
- Channel-level open wire detection for 4-20mA loops.
- Power supply fault monitoring.
- Communication status per trunk via NetCon controller.
- Rotary switch position verification through software.
Certifications & Compliance
- Designed to meet industrial control standards (CE marked as per Woodward).
- Humidity tested: 95% for 48 hours at 20°C and 55°C – non-condensing.
- Isolation rated for 500V between power and I/O, safe for industrial panels.
- RoHS compliant (standard for Woodward products).
Package Contents
- 1 x Woodward 9905-969 Linknet Analog Input Module
- Phoenix terminal housing (pre-assembled)
- Quick start guide (digital copy available)
- No cables included – order separately.
Warranty & Shipping
- 12 months warranty from invoice date. Covers manufacturing defects.
- Shipping partners: FedEx, UPS, DHL – worldwide express delivery.
- Tracking number provided within 24 hours. Insurance included.
- Stock ready for immediate dispatch.
Frequently Asked Questions (FAQ)
- Question: What is the maximum number of 9905-969 modules on one network?
Answer: Up to 60 modules per trunk. Four trunks give you 240 total modules.
- Question: Does this module support HART protocol?
Answer: No. It reads pure 4-20mA signals only. No HART overlay.
- Question: Can I use this module outdoors?
Answer: Yes if placed in a weatherproof cabinet. Temperature range –40°C to +55°C.
- Question: How do I set the network address?
Answer: Use two rotary switches. Set from 1 to 60. Match MOE coder configuration.
Experience-based Q&A (Field Notes)
- Question: My module shows no communication. What should I check first?
Answer: Verify power supply (24Vdc) and rotary switch settings. Also check twisted pair polarity.
- Question: Can I replace a failed module without shutting down the whole system?
Answer: No. Power off the trunk before removing or installing the module.
- Question: The 4-20mA reading is unstable. What causes this?
Answer: Check for ground loops or loose wiring. Use shielded cables for analog signals.
Buying Guide & Selection Advice
- Choose Woodward 9905-969 if you need 6 analog inputs for NetCon systems.
- Need more channels? Consider discrete input modules (16 channels) or relay output (8 channels).
- For temperature sensing, pick thermocouple or RTD LINKnet modules instead.
- Verify your NetCon controller firmware version – older versions may have module limits.
- Order extra modules for future expansion. Each trunk supports 60 nodes.
- Contact us for bulk pricing or cross-reference to older Woodward part numbers.
Contact & Support
- Have questions? Talk to our engineers:
+86 158 8020 0923 (WhatsApp) - Email: support@plcdcshub.com – reply within 24 hours.
- Pre-sales consulting, datasheets, and RMA support available.
Copyright © 2026 PLCDCS HUB Limited. All rights reserved.
Original Source: https://plcdcshub.com/
Partner: Powergear X Automation Limited |
Oiltech Controls Limited











0.0 Average Rating Rated (0 Reviews)