More items from this sellerView All

Description

Product Overview

IS200TTURH1C is a Terminal Board from General Electric. It belongs to the Mark VI series. This board works with GE’s later Speedtronic systems, including Mark VI and Mark VIe. Use it for turbine control in power plants.

Key Benefits

  • Controls generator synchronization with PTUR and VTUR boards
  • Switch between simplex or TMR voting using two jumpers
  • Many surface-mounted relays for reliable switching
  • Works with both Mark VI and Mark VIe systems
  • Numbered screw connectors for easy wiring

Technical Specifications

  • Brand: General Electric (GE)
  • Part Number: IS200TTURH1C
  • Series: Mark VI
  • Product Type: Turbine Control Terminal Board
  • Compatible systems: Mark VI, Mark VIe, later Speedtronic

Order Code – Tree Structure

  • IS200 = GE Industrial Systems family
  • TTUR = Turbine Terminal board type
  • H = Functional revision level
  • 1C = Artwork/component revision

Board Layout & Components

  • Shape: Rectangular with small cutouts
  • Surface-mounted relays: Many (quantity not specified)
  • Variable resistors: Yes, for adjustments
  • Transformers: Two, near board center
  • Jumper switches: Two, for simplex or TMR voting

Connectors & Terminals

  • D-shell connectors: Male and female types
  • Plug connectors: For board-to-board links
  • Terminal blocks: Two large main blocks
  • Screw connectors: Numbered for easy reference

Compatibility & System Integration

  • Works with PTUR and VTUR boards
  • Controls generator synchronization via hardware connections
  • Supports simplex (single channel) mode
  • Supports TMR voting (triple modular redundancy) mode
  • Use jumpers to select mode

Installation Guide

  • Mount board in Mark VI or Mark VIe cabinet
  • Connect PTUR and VTUR boards using plug connectors
  • Use numbered screw terminals for field wiring
  • Set jumpers before powering up – simplex or TMR
  • Keep board dry and free from conductive dust

Maintenance & Diagnostics

  • Visual check of relays and transformers
  • Test variable resistor adjustments with meter
  • No onboard LEDs – use system diagnostics
  • Replace board if relays show pitting or sticking
  • Keep spare for critical turbine systems

Environmental & Handling

  • Use in clean, dry control rooms only
  • Avoid vibration near turbine deck
  • Temperature: 0 to 50°C typical
  • Humidity: 5% to 95% non-condensing
  • Handle by edges – avoid touching components

Packing List

  • 1x GE IS200TTURH1C Terminal Board
  • Anti-static bag
  • No cables or connectors included
  • Original factory packing (where available)

Warranty & Shipping

  • 12-month factory warranty
  • Fast global shipping: FedEx, UPS, DHL
  • Tracking number for every order

Typical Applications

  • Gas turbine generator synchronization
  • Steam turbine speed control systems
  • Mark VI and Mark VIe retrofit projects
  • Power plant excitation control
  • Industrial turbine protection systems

5 Professional FAQs

  • What is the difference between simplex and TMR mode on this board?
  • Simplex uses one control channel. TMR uses three channels with voting for higher reliability.
  • Can I use IS200TTURH1C with older Mark V turbines?
  • No. This board works only with Mark VI and Mark VIe systems. Not compatible with earlier Speedtronic versions.
  • How do I know if my board needs replacement?
  • Look for burned relays, cracked transformers, or failed generator sync. Also check for loose screw terminals.
  • Do you sell the PTUR and VTUR boards that work with this terminal board?
  • Yes. Please contact us for pricing on PTUR and VTUR boards. We can bundle them together.
  • What happens if I set the jumpers incorrectly?
  • Wrong jumper setting causes control errors. The generator may not sync properly. Always verify before startup.

Selection Guide – Pick the Right Mark VI Terminal Board

  • Step 1 – Identify your turbine control system: IS200TTURH1C fits Mark VI and Mark VIe. Do not buy for Mark V or older.
  • Step 2 – Choose simplex or TMR: For critical turbines, pick TMR mode. For smaller or backup units, simplex may be enough.
  • Step 3 – Check companion boards needed: You will likely need PTUR and VTUR boards. Order all three together for complete sync control.
  • Step 4 – Verify connector types: Your cabinet must have matching D-shell and plug connectors. Adapters may be needed for older racks.
  • Pro tip: Take photos of your old board’s jumper settings before removal. This makes installation of the new board much faster.

Contact Information

Need help with TMR configuration or compatibility? Talk to us on WhatsApp: +86 158 8020 0923. We reply fast.

Browse other GE turbine parts in our VersaMax collection.

Copyright © 2026 PLCDCS HUB Limited. All rights reserved.
Original Source: https://plcdcshub.com/
Partner: Powergear X Automation Limited
Oiltech Controls Limited

0.0 Average Rating Rated (0 Reviews)

Rated
0%
Rated
0%
Rated
0%
Rated
0%
Rated
0%

Be the first to review “GE IS200TTURH1C Terminal Board – Mark VI Turbine Control”

Your email address will not be published. Required fields are marked *

You have to login to add images.