More items from this sellerView All

Description

Key Features for 330851-02-000-066-90-00-05

  • ???? 66mm Mid-Size Case (Code 066)
  • ???? 9m Industrial Cable (Code 90)
  • ???? Multi-Certified (Code 05)
  • ???? 8.8Ω ±1.1 at 9m Length

Full Model Code Details for 330851-02-000-066-90-00-05

Code Description
02 M30x2 Threaded
000 0in Unthreaded
066 66mm Case
90 9.0m Cable
00 No Armor
05 ATEX + IECEx + ABS

Technical Specifications

Parameter Value
Resistance (9m) 8.8Ω ±1.1
Operating Temp -35°C to +200°C
Peak Temp 250°C (24hr max)
Cable Type 75Ω Triaxial PFA
Weight 230g (8.1oz)

Installation

  • ⚙️ Max Torque: 163 N·m (120 ft·lb)
  • ⚙️ Safe Torque: 68 N·m (50 ft·lb)
  • ⚙️ Compatibility: Replaces 7200 35mm Systems

Certifications

  • ???? ATEX Zone 0/Zone 2
  • ???? IECEx Ex ia IIC T4
  • ???? ABS Marine Certified
  • ???? FCC & EN 61000 EMC

Application Example

Monitors mining conveyor motors detecting bearing failures in high-dust environments (+170°C).

Package Includes

  • ???? 1x Probe (66mm Case)
  • ???? 9m PFA Cable
  • ???? 1-Year Heavy-Duty Warranty

Contact

Email: sales@ubestplc.com

Download official datasheet here: 3300-XL-25MM-Datasheet

Recommended Bently Nevada Probes

330851-02-000-050-50-01-CN 330851-02-000-070-50-00-CN 330851-02-000-066-50-00-CN
330851-02-000-080-50-01-CN 330851-02-000-060-50-00-CN 330851-02-000-030-50-00-CN
330851-02-000-050-50-00-CN 330851-02-000-040-90-00-00 330851-02-000-080-90-01-00
330851-02-000-080-90-00-00 330851-02-000-030-90-00-00 330851-02-000-060-90-00-00
330851-02-000-066-90-00-00 330851-02-000-070-90-00-00 330851-02-000-050-90-00-00

Additional information

Weight 0.323 kg
Dimensions 300 × 330 × 60 mm

0.0 Average Rating Rated (0 Reviews)

Rated
0%
Rated
0%
Rated
0%
Rated
0%
Rated
0%

Be the first to review “Bently Nevada – Proximity Probe M30x2 Thread 330851-02-000-066-90-00-05”

Your email address will not be published. Required fields are marked *

You have to login to add images.